Displacement Sensor Specifications
DISPLACEMENT SENSORS WITH STANDARD OUTPUTS
Model Type |
|||||||
Model Range |
LDS-xx |
LDS |
|||||
05 |
10 |
25 |
50 |
100 |
|||
Feature | Units | ||||||
Displacement | mm | 5.5 |
11 |
26 |
51 |
101 |
|
inch | 0.2 |
0.4 |
1.0 |
2.0 |
4.0 |
||
Weight (excluding cable) | grams | 125 / 135 |
130 / 140 |
140 / 150 |
180 / 200 |
320 |
|
Spindle Force | gf | 150-400 |
50-300 |
50-300 |
50-250 |
120-400 |
|
Sensitivity (nominal) | mV/mm | 4.2 / 4.6 |
2.5 / 2.8 |
1.3 / 1.5 |
0.9 / 0.96 |
0.38 |
|
Output FS (nominal) | mV/V | 4.2 / 4.6 |
5.1 / 5.6 |
6.7 / 7.2 |
9.0 / 9.6 |
7.5 |
Non-Linearity, Hysteresis, Repeatability (total error) | %FS | <0.1 |
<0.2 |
Dim A | mm | 110 |
115 |
146 |
230 |
390 |
|
Dim B | mm | 78.5 |
78.5 |
94 |
155 |
264 |
|
Dim C | mm | Ø17.4 |
Ø25.4 |
||||
Bridge Resistance | Ohms | 350 |
|||||
Excitation AC or DC | volts | 2-10 |
|||||
Current consumption | mA | <30 @ 10vdc |
|||||
Insulation Resistance | MΩ | >2000 |
|||||
Resolution | Infinite |
||||||
Operating Temperature | °C | -10 to +70 |
|||||
Temperature Effect |
Zero | <0.01% / °C |
|||||
Output | <0.01% / °C |
||||||
Environmental Protection | IP 54 |
||||||
Standard Termination* | 2mtrs 4 core screened cable (min bend radium 10mm) |
||||||
Electrical Connections | Input + |
Input - |
Output + |
Output - |
|||
*other options available | Red |
Blue |
Green |
Yellow |
|||
With Plug Fitted | 5 pin Din 240° |
Pin 1 |
Pin 2 |
Pin 4 |
Pin 5 |
PHYSICAL DIMENSIONS
(Refer to table above for measurements)
WIRING SCHEMATIC FOR STANDARD mV/V OUTPUT SENSORS
NB. As a result of continuous development, the specification of our linear displacement sensors may be subject to alteration.
Click here to download
this page as a PDF (87k)
To view PDF files requires Adobe Reader.